BCD to 7 segment decoder

using the part in-scene § part parameters

 

Using the part in-scene

Useful facts

  • The outputs "a" to "g" should be connected via resistors to the corresponding terminals of a 7-segment display.

 

  • The binary coded decimal inputs "A" to "D" can be connected directly to the BCD decade counter.

 

  • When the "LT" test input is '0', all segments are turned on.

 

  • When the "BI" input is '0' (and the "LT" input is '1'), all the segments are blanked.

 

  • When the "EL" input goes from '0' to '1' the inputs "A" to "D" are latched and the outputs remain fixed until "EL" goes low again.

 

  • The 4511 decoder displays old style 6 and 9 digits.

 

 

 

 

Part Parameters

The part is based on the 4511 BCD to 7-segment latch, decoder and drive. Other parameters vary according to the logic family selected in the scene's Properties pane (Electronics):

 

 

74HC

4000B

  • (Hidden) supply voltage (VDD)

2-6V

3-15V

  • Output drive current (IO)

4mA

0.4mA

  • Maximum output (low voltage)

0.4V (IO=4mA)

0.4V (IO=0.4mA)

  • Minimum output (high voltage (VDD=5V))

0.4V (IO=4mA)

0.4V (IO=0.4mA)

  • Maximum voltage (for '0' input)

30% of VDD

30% of VDD

  • Minimum voltage (for '1' input)

70% of VDD

70% of VDD

  • Maximum output current

50mA

50mA

  • Minimum input voltage

-1V

-1V

  • Maximum input voltage

VDD + 1V

VDD + 1V

 

To ensure that an input voltage to a logic IC is recognised as a binary value, it must meet the above-specified Maximum voltage (for '0' input) or Minimum voltage (for '1' output), otherwise the input will have an undefined logic value.